Paid
SERVICE DESCRIPTION | High-Precision Stable Isotope Ratio Analysis Services (¹³C, ¹⁸O, ²H) for Environmental and Biomolecular Research Enhance the quality of your research with stable isotope ratio analysis using EA-IRMS (Elemental Analyzer–Isotope Ratio…
- Laboratorium Karakterisasi Kimia (MIP)
- PT. Integrasi Lab Indonesia
- KST Serpong (Bacharuddin Jusuf Habibie)
KST. BJ Habibie, Gedung SBSN dan 456, Laboratorium Kimia BRIN - ILI Serpong Tangerang Selatan, Banten 15314 - 08119811561
- sales@labindonesia.co.id
Marketing Office
Deputi Bidang Infrastruktur Riset dan Inovasi BRIN
-
High-Precision Stable Isotope Ratio Analysis Services (¹³C, ¹⁸O, ²H) for Environmental and Biomolecular Research
Enhance the quality of your research with stable isotope ratio analysis using EA-IRMS (Elemental Analyzer–Isotope Ratio Mass Spectrometry) and GasBench IRMS technology. These technologies enable accurate and efficient isotope ratio analysis of various sample types, including organic solids and water.
Sample Requirements
Solid samples: minimum 5 g; particle size below 100 mesh.
Water samples: minimum 10 mL. 📞 Consultation & Service Info:
Application Requirements:
Enhance the quality of your research with stable isotope ratio analysis using EA-IRMS (Elemental Analyzer–Isotope Ratio Mass Spectrometry) and GasBench IRMS technology. These technologies enable accurate and efficient isotope ratio analysis of various sample types, including organic solids and water.
- EA-IRMS is used to measure carbon isotope ratios (δ⊃1;⊃3;C) in organic samples and is ideal for studies of plant nutrition, biomolecules, and isotope tracing in living organisms.
- GasBench II IRMS is used to analyze stable oxygen (δ⊃1;⁸O) and deuterium (δ⊃2;H) isotopes in water samples through the water-equilibration method. This is highly relevant to hydrology, climate-change, and geoecology studies.
- The maximum number of samples for ⊃1;⊃3;C analysis is 3 samples.
- The maximum number of samples for ⊃1;⁸O and ⊃2;H analysis is 6 samples.
- Requests exceeding the limits above must be submitted separately.
- ⊃1;⊃3;C isotope analysis using EA-IRMS — IDR 2,000,000 / sample / parameter
- ⊃1;⁸O isotope analysis (water) using GasBench-IRMS — IDR 2,250,000 / sample / parameter
- ⊃2;H isotope analysis (water) using GasBench-IRMS — IDR 2,250,000 / sample / parameter
Sample Requirements
Solid samples: minimum 5 g; particle size below 100 mesh.
Water samples: minimum 10 mL. 📞 Consultation & Service Info:
- Technical consultation: https://wa.me/6282120120100
- Status check & complaints: https://wa.me/628119811561
Application Requirements:
- Photo
- Other Supporting File
| File Name | File Size | |
|---|---|---|
| Service SOP/Form file | 0.17 MB | |
| Template Photo | 0 MB | |
| Template Other Supporting File | 0 MB |