SERVICE DESCRIPTION | Analysis using Gas Chromatography–Flame Ionization Detector (GC-FID) is an instrumental analytical method used for the separation, identification, and quantification of volatile and semi-volatile organic compounds. Gas Chromatography–Electron Capture…
- Laboratorium Kimia dan Bioproses - Laboratorium Kimia (MIP)
- PT. Integrasi Lab Indonesia
- KST Serpong (Bacharuddin Jusuf Habibie)
KST. BJ Habibie, Gedung SBSN dan 456, Laboratorium Kimia BRIN - ILI Serpong Tangerang Selatan, Banten 15314 - 08119811561
- sales@labindonesia.co.id
Marketing Office
Deputi Bidang Infrastruktur Riset dan Inovasi BRIN
layanan_sains@brin.go.id
Analysis using Gas Chromatography–Flame Ionization Detector (GC-FID) is an instrumental analytical method used for the separation, identification, and quantification of volatile and semi-volatile organic compounds. Gas Chromatography–Electron Capture Detector (GC-ECD) is a gas chromatography analysis technique used to detect compounds with a high affinity for electrons, particularly those containing electronegative elements such as halogens (Cl, Br, F), nitro, or certain carbonyl groups. This method is highly sensitive and selective, making it widely used in trace analysis, particularly in the environmental and food sectors. The results of GC-FID and GC-ECD analyses are displayed in the form of chromatograms, graphs that show the relationship between retention time (x-axis) and signal intensity (y-axis). Each peak in the chromatogram represents a single component in the sample. Compound identification is performed by comparing the sample's retention time with that of a standard, while quantification is based on the peak area compared to a calibration curve. Currently, the standard is only available for hydrocarbons from C6 to C21. For other standards, please contact the laboratory service department.
IMPORTANT
-
The maximum number of samples permitted is 5.
-
Any submission exceeding 5 samples must be filed separately.
Consultation and questions about testing services:
https://wa.me/6282120120100
Service status information and complaints:
https://wa.me/628119811561
Additional information:
- Samples that have been tested will be stored in the laboratory for a maximum of 3 months.
- Samples not taken within this time will be destroyed
- Maximum payment time is one month (1 month) after the Billing Code is issued