Paid
SERVICE DESCRIPTION | Cytation™ 5 combines automated digital microscopy and conventional microplate detection in a configurable, upgradeable platform. The microscopy module offers up to 60x magnification in fluorescence, brightfield, high contrast brightfield, color…
- Laboratorium Genomik - Fasilitas Layanan Sel dan Citra Seluler
- KST Cibinong (Soekarno)
Gedung Genomik - KST Soekarno (BRIN Cibinong) Jl. Raya Bogor KM 46, Cibinong, Kec. Cibinong, Kab. Bogor, Jawa Barat, 16911 - 08119811575
- genomik@brin.go.id
Marketing Office
Deputi Bidang Infrastruktur Riset dan Inovasi BRIN
layanan_sains@brin.go.id
Cytation™ 5 combines automated digital microscopy and conventional microplate detection in a configurable, upgradeable platform. The microscopy module offers up to 60x magnification in fluorescence, brightfield, high contrast brightfield, color brightfield and phase contrast for maximum application reach. The multi-mode detection modules include filter- and monochromator-based fluorescence detection, luminescence, and UV-Vis absorbance detection. Gen5™ software provides complete control over all imaging and data capture, plus powerful image and data analysis.
Imaging
- Imaging with magnification
- 1.25X PL APO
- 2.25X PL ACH Meiji
- 4X PL FS Phase
- 10X PL FS Phase
- 20X PL FS Phase
- 60x PL FS
- Z-Stack
- Montage
- Kinetic Imaging (limited if CO2 gas is available)
Includes multimode reading
- Absorbance
- Fluorescence
- Luminescence
Fluorochrome types
DAPI 377,447
GFP 469,525
RFP 531,593
Texas Red 586,647
Bright Field
Phase contrast
Color Bright Field
Vessel type
Microplate 6-well – 1536-well
Slide
Labware
Petri dish
Flask
Notes for Elsa Cytation-5 service users
1. Sample preparation is performed by the researcher, while instrument operation is performed by the instrument operator
2. Plates/Slides/Labware/Petri dishes/Flasks are provided by the researcher
3. Materials and supplies for sample preparation are not part of the Elsa Cytation-5 service
4. Must be present at the location during reading
Note: To facilitate verification of registered test samples, customers must complete the TEST DETAIL FORM, which can be downloaded from the “Service Documents” section --> “Service SOP Documents” section, and then the completed form (in .pdf format) must be uploaded along with the sample photo in the “Other Supporting Files” and “Photo Data Files” sections. Ensure that the name and number of samples registered in the ELSA System match the number of samples listed on the form.
Incomplete supporting documents may result in the sample registration being canceled by the Verifier.
Assistance is provided by ASN users accompanied by OA/laboratory managers.
For further information, please contact the genomic laboratory service number at 08119811575.
Application Requirements:
Imaging
- Imaging with magnification
- 1.25X PL APO
- 2.25X PL ACH Meiji
- 4X PL FS Phase
- 10X PL FS Phase
- 20X PL FS Phase
- 60x PL FS
- Z-Stack
- Montage
- Kinetic Imaging (limited if CO2 gas is available)
Includes multimode reading
- Absorbance
- Fluorescence
- Luminescence
Fluorochrome types
DAPI 377,447
GFP 469,525
RFP 531,593
Texas Red 586,647
Bright Field
Phase contrast
Color Bright Field
Vessel type
Microplate 6-well – 1536-well
Slide
Labware
Petri dish
Flask
Notes for Elsa Cytation-5 service users
1. Sample preparation is performed by the researcher, while instrument operation is performed by the instrument operator
2. Plates/Slides/Labware/Petri dishes/Flasks are provided by the researcher
3. Materials and supplies for sample preparation are not part of the Elsa Cytation-5 service
4. Must be present at the location during reading
Note: To facilitate verification of registered test samples, customers must complete the TEST DETAIL FORM, which can be downloaded from the “Service Documents” section --> “Service SOP Documents” section, and then the completed form (in .pdf format) must be uploaded along with the sample photo in the “Other Supporting Files” and “Photo Data Files” sections. Ensure that the name and number of samples registered in the ELSA System match the number of samples listed on the form.
Incomplete supporting documents may result in the sample registration being canceled by the Verifier.
Assistance is provided by ASN users accompanied by OA/laboratory managers.
For further information, please contact the genomic laboratory service number at 08119811575.
Application Requirements:
- Photo
- Other Supporting File
File Name | File Size | |
---|---|---|
Service SOP/Form file | 0.37 MB | |
Template Photo | 0 MB | |