SERVICE DESCRIPTION | The EVOS M7000 Fluorescence Microscope is a fully automated digital microscope system designed for observing live cells and fixed specimens, with high-quality brightfield, phase contrast, and multi-channel fluorescence (DAPI, GFP, RFP) capabilities.…
- Laboratorium Genomik - Fasilitas Layanan Sel dan Citra Seluler
- KST Cibinong (Soekarno)
Gedung Genomik-KST Soekarno (Cibinong) BRIN Jl Raya Bogor KM 46, Cibinong, Kab. Bogor, Jawa Barat - 08119811575
- genomik@brin.go.id
Marketing Office
Deputi Bidang Infrastruktur Riset dan Inovasi BRIN
layanan_sains@brin.go.id
The EVOS M7000 Fluorescence Microscope is a fully automated digital microscope system designed for observing live cells and fixed specimens, with high-quality brightfield, phase contrast, and multi-channel fluorescence (DAPI, GFP, RFP) capabilities.
This instrument is equipped with a high-resolution digital camera, a heat-efficient LED lighting system, and an integrated incubation system to maintain optimal cell culture conditions (temperature, CO₂, and humidity) during long-term observation (time-lapse imaging). The obtained fluorescence images can then be analyzed using the user-friendly EVOS analysis software.
Specifications: Inverted Fluorescence Microscope.
Sample type/preparation: Cells or tissues on glass slides or in well plates (ready for analysis).
Service contract for live imaging:
□ Live Imaging without Fluorescence (Brightfield/Phase Contrast)
□ Live Imaging with Fluorescence
Samples without preparation (ready for analysis/run)
Translated with DeepL.com (free version)
Note:
Note:
To facilitate the verification of registered test samples, customers must complete the TEST DETAILS FORM, which can be downloaded from the “Service Files” section --> “Service SOP Documents” section, and then upload the completed form (in .pdf format) along with the sample photo in the “Additional Support Files” and “Photo Data Files” sections. Ensure that the name and number of samples/contracts registered in the ELSA System match the number of samples/contracts listed on the form.
Incomplete supporting documents may result in the sample registration being canceled by the Verifier.
IT IS MANDATORY TO INCLUDE THE TESTING TIME (START TIME) IN THE SAMPLE DESCRIPTION.
Assistance is provided by the OA/laboratory manager
For further information, please contact the genomic laboratory service number at 08119811575
Application Requirements:
- Photo
- Other Supporting File
File Name | File Size | |
---|---|---|
Service SOP/Form file | 0.13 MB | |
Template Photo | 0 MB | |
Template Other Supporting File | 0 MB |