SERVICE DESCRIPTION | Moisture Analyzer Shimadzu MOC63u Service The Shimadzu MOC63u Moisture Analyzer is an analytical instrument used to determine the moisture content of various solid samples quickly and accurately. The instrument operates using an infrared (IR) heating…

  • iLaB (Integrated Laboratory of Bioproducts) - ORNM
  • KST Cibinong (Soekarno)
    KST Ir Soekarno
  • 087884931709
  • maya007@brin.go.id
  • Service Unit: Contractual (per sample)
  • Service Duration: 1 Working Days
  • Service Quota Per Day: 8
  • Service Capacity: 1 Contractual (per sample)
  • Minimum Amount: 1
Marketing Office
Deputi Bidang Infrastruktur Riset dan Inovasi BRIN
-
Apply for Service
Moisture Analyzer Shimadzu MOC63u Service

The Shimadzu MOC63u Moisture Analyzer is an analytical instrument used to determine the moisture content of various solid samples quickly and accurately. The instrument operates using an infrared (IR) heating and drying method, while continuously monitoring the change in sample weight during the drying process until a stable moisture content is obtained.

Service

Measurement of sample moisture content using the Shimadzu MOC63u Moisture Analyzer through a controlled heating and drying process.

Service Specifications
  • Equipment: Moisture Analyzer
  • Brand/Model: Shimadzu MOC63u
  • Measured parameter: Moisture Content
  • Method: Infrared (IR) heating and drying
  • Sample: Solid samples, ready for analysis and prepared by the user
  • Sample preparation: Not included in the service
  • Output: Moisture content (%) and/or dry matter content (%)
  • Operation: Performed by the user in accordance with the equipment SOP and under laboratory staff supervision
Conditions of Use
  1. Samples must be ready for analysis, and the sample type and quantity must be provided before testing.
  2. Samples must be homogeneous and representative of the material being analyzed.
  3. The user is responsible for ensuring that the sample is safe for the heating process.
  4. Samples must not generate toxic, corrosive, or flammable gases, or any substances that may endanger the user or damage the equipment during measurement.
  5. The sample quantity must comply with the sample pan capacity and the recommended operating conditions of the instrument.
  6. Users must follow the applicable equipment SOP and laboratory safety procedures.
  7. For optimal results, the measurement method and drying conditions should be appropriate for the characteristics of the sample.
  8. Measurement results may be affected by sample homogeneity, particle size, drying temperature, and sample condition.