Paid
SERVICE DESCRIPTION | MiSeq is one of Illumina’s next generation sequencing (NGS) instrument. It can be used to sequence 24 small genomes, 96 amplicon samples, or 96 samples of 16S rRNA metagenomic analysis. Available reagents • v2 (50, 300 and 500 cycles) • v3 (150…
- Laboratorium Pusat Sekuensing
- KST Cibinong (Soekarno)
Alamat Pengantaran Sampel: Gedung BSL3 KST Soekarno Cibinong-BRIN Jl. Raya Bogor KM 46. Kabupaten Bogor 16911 An. Rohmatullah (089638118285) - 08119811577
- pusatsekuensing@brin.go.id
MiSeq is one of Illumina’s next generation sequencing (NGS) instrument. It can be used to sequence 24 small genomes, 96 amplicon samples, or 96 samples of 16S rRNA metagenomic analysis.
Available reagents
• v2 (50, 300 and 500 cycles)
• v3 (150 and 600 cycles)
Run Time: 4–55 hours
Maximum Output: 15 Gb
Maximum Reads Per Run: 25 million
Maximum Read Length: 2 × 300 bp
NextSeq 550 is one of Illumina's flexible benchtop sequencing system for exome, transcriptome, and whole-genome sequencing.
Run Time: 12–30 hours
Maximum Output: 120 Gb
Maximum Reads/Run: 400 million
Maximum Read Length: 2 × 150 bp
NovaSeq series is Illumina's highest capacity sequencer. It provides variety of sequencing reagents and flow cells to accomodate broad range of samples to be sequenced in one run.
Run Time:
~13–38 hours (dual SP flow cells)
~13–25 hours (dual S1 flow cells)
~16–36 hours (dual S2 flow cells)
~44 hours (dual S4 flow cells)
Maximum Output: 6000 Gb
Maximum Reads Per Run: 20 billion
Maximum Read Length: 2 x 250 bp
Application Requirements:
Available reagents
• v2 (50, 300 and 500 cycles)
• v3 (150 and 600 cycles)
Run Time: 4–55 hours
Maximum Output: 15 Gb
Maximum Reads Per Run: 25 million
Maximum Read Length: 2 × 300 bp
NextSeq 550 is one of Illumina's flexible benchtop sequencing system for exome, transcriptome, and whole-genome sequencing.
Run Time: 12–30 hours
Maximum Output: 120 Gb
Maximum Reads/Run: 400 million
Maximum Read Length: 2 × 150 bp
NovaSeq series is Illumina's highest capacity sequencer. It provides variety of sequencing reagents and flow cells to accomodate broad range of samples to be sequenced in one run.
Run Time:
~13–38 hours (dual SP flow cells)
~13–25 hours (dual S1 flow cells)
~16–36 hours (dual S2 flow cells)
~44 hours (dual S4 flow cells)
Maximum Output: 6000 Gb
Maximum Reads Per Run: 20 billion
Maximum Read Length: 2 x 250 bp
Application Requirements:
- Cover Letter
- Other Supporting File
File Name | File Size | |
---|---|---|
Service SOP file | 0.07 MB | |
Template Cover Letter | 0 MB | |
Template Other Supporting File | 0 MB |