Rp 750.000


SERVICE DESCRIPTION | Tool Functions and Testing Limitations: Raman Spectroscopy is an instrument that measures molecular vibration based on inelastic scattering phenomenon. Raman spectroscopy is a non-destructive chemical analysis characterization that provides detailed…

  • Laboratorium Imaging Fisika Maju
  • KST Serpong (Bacharuddin Jusuf Habibie)
    KST BJ Habibie Gedung 440-442 Laboratorium Imaging Fisika Maju Badan Riset dan Inovasi Nasional
  • 08119811562
  • labkarserpong@brin.go.id
  • Service Unit: Per Sample
  • Service Duration: 14 Working Days
  • Service Quota Per Day: 4
  • Service Capacity: 1 Per Sample
  • Minimum Amount: 1
Marketing Office
Deputi Bidang Infrastruktur Riset dan Inovasi BRIN
layanan_sains@brin.go.id
Apply for Service
Tool Functions and Testing Limitations:
Raman Spectroscopy is an instrument that measures molecular vibration based on inelastic scattering phenomenon. Raman spectroscopy is a non-destructive chemical analysis characterization that provides detailed information about the identification of molecules, molecular analysis, phase and polymorphy, crystallinity, molecular interactions, analysis of carbon-based materials, and analysis of inorganic materials. Raman analysis can provide key information (qualitative or quantitative) easily and quickly. Our Raman spectroscopy can measure bulk, powder, thin film, or liquid samples. Applications of Raman spectroscopy: Carbon materials (carbon nanotubes, graphene, carbon-based materials), pharmaceuticals and cosmetics (example compound distribution, drugs, contaminant identification), life sciences (example DNA/RNA analysis), geology and mineralogy (example gemstone and mineral identification).
 

Notes:

1. Before clicking Request a Service, please see the available SCHEDULE first.

2. To facilitate verification of registered test samples, customers must complete Form F-10 which can be downloaded in the "Service Files" section then select "Service SOP Files". Form F-10 that has been filled in. PDF format is uploaded along with Sample Photos in the "Other Supporting Files" and "Photo Data Files" sections.

3. Make sure that the NAME and NUMBER OF SAMPLES registered with ELSA are the same as the NUMBER OF SAMPLES written on Form F-10.

4. Incompleteness of these supporting documents may cause the test sample registration to be canceled by the Laboratory Management.

5. Refunds cannot be made unless there are technical problems at the Laboratory.

6. If the sample will be taken again. The maximum time limit for sampling is 1 month (30 working days) after the test has been completed.


 

Application Requirements:
  • Photo
  • Other Supporting File
File Name File Size
Service SOP file 0.16 MB
Template Photo 0 MB
Template Other Supporting File 0 MB