SERVICE DESCRIPTION | Probe Sonicator Q2000 Service The Probe Sonicator Q2000 is an instrument used for sample sonication and homogenization using high-intensity ultrasonic waves. Sonication can facilitate the disruption, dispersion, homogenization, emulsification, and extraction…

  • iLaB (Integrated Laboratory of Bioproducts) - ORNM
  • KST Cibinong (Soekarno)
    KST Ir Soekarno
  • 087884931709
  • maya007@brin.go.id
  • Service Unit: Contractual (per sample/hour)
  • Service Duration: 1 Working Days
  • Service Quota Per Day: 4
  • Service Capacity: 1 Contractual (per sample/hour)
  • Minimum Amount: 1
Marketing Office
Deputi Bidang Infrastruktur Riset dan Inovasi BRIN
-
Apply for Service
Probe Sonicator Q2000 Service

The Probe Sonicator Q2000 is an instrument used for sample sonication and homogenization using high-intensity ultrasonic waves. Sonication can facilitate the disruption, dispersion, homogenization, emulsification, and extraction of components from various samples, particularly suspensions and liquid samples.

Service

Operation of the Probe Sonicator Q2000 for sample sonication, homogenization, dispersion, emulsification, and extraction using ultrasonic energy according to the operating conditions specified by the user.

Service Specifications
  • Equipment: Probe Sonicator

  • Brand/Model: Q2000

  • Functions: Sonication, homogenization, dispersion, emulsification, and extraction

  • Sample type: Solutions, suspensions, and liquid samples suitable for sonication

  • Sample: Ready-to-process samples prepared by the user

  • Sample preparation: Not included in the service

  • Output: Sonicated sample according to the specified operating parameters

  • Operating parameters: Amplitude, sonication time, and pulse mode are adjusted according to the sample characteristics and user's requirements

  • Operation: Performed by the user in accordance with the equipment SOP and under laboratory staff supervision

Conditions of Use
  1. The user must provide information regarding the sample type, volume, and characteristics before using the equipment.

  2. Samples must be suitable for sonication and have an adequate volume for probe operation.

  3. The user must use a suitable sample container that is resistant to the sonication process.

  4. Samples that are flammable, explosive, or may generate toxic, corrosive, or hazardous gases/vapors are not permitted.

  5. The user must ensure that the probe is properly immersed in the sample and does not touch the bottom or walls of the container during sonication.

  6. Sonication parameters such as amplitude, sonication time, and pulse cycle must be adjusted according to the sample characteristics to prevent excessive heating or sample damage.

  7. For heat-sensitive samples, the use of pulse mode or an appropriate cooling system is recommended.

  8. The probe must be cleaned before and after use in accordance with the equipment SOP to prevent cross-contamination.

  9. Users must comply with the applicable equipment SOP and laboratory safety procedures.

  10. The user is responsible for ensuring the safety and suitability of the sample throughout the sonication process.

Equipment Operating Hours
  • Session 1: 09:00–10:00 WIB

  • Session 2: 10:30–11:30 WIB

  • Session 3: 13:00–14:00 WIB

  • Session 4: 14:30–15:30 WIB

Scheduling Requirements
  1. Please specify the requested testing time/session in the service request description according to the available time slots listed above. If the required operating time exceeds the selected session, please submit the request for two sessions.

  2. The actual operation must be conducted according to the scheduled time.

  3. Service requests that do not specify the requested service time in the ELSA description field, or requests submitted outside the available service hours, will be rejected.



File Name File Size
Service SOP/Form file 0.33 MB