SERVICE DESCRIPTION | This instrument is used for the quantitative analysis process of volatile organic chemical compounds such as alcohol, short chain fatty acids, essential oils. Samples received without preparation are in the form of a solution which will be filtered with…
- Laboratorium Kawasan Yogyakarta
- KST Gunung Kidul (Umar Anggara Jenie)
Kawasan Sains Umar Anggara Jenie BRIN, Jl. Jogja-Wonosari km 31,5, Desa Gading, Kec. Playen, Gunungkidul – Yogyakarta 55861 - 08119811586
- labkarplayen@brin.go.id
Marketing Office
Deputi Bidang Infrastruktur Riset dan Inovasi BRIN
layanan_sains@brin.go.id
This instrument is used for the quantitative analysis process of volatile organic chemical compounds such as alcohol, short chain fatty acids, essential oils. Samples received without preparation are in the form of a solution which will be filtered with a 0.2 µm syringe filter at the Advanced Characterization Laboratory, KS Umar Anggara Jenie, Gunungkidul.
Specifications:
GC – FID, Thermo Fisher Scientific
Column type:
Usage Hours
Hours: 09.00 - 15.00 WIB on weekdays
Provision :
Sample requirements:
The sample is a volatile compound, the sample dissolves completely in the solvent and there is no precipitate
Sample delivery address
Laboratorium Kawasan Yogyakarta
Kawasan Sains Umar Anggara Jenie BRIN, Jl. Jogja-Wonosari km 31,5, Desa Gading, Kec. Playen, Gunungkidul – Yogyakarta 55861
For further information, please contact us on WA number +628119811586
Application Requirements:
Specifications:
GC – FID, Thermo Fisher Scientific
Column type:
- TG5 MS (30 m x 0.25 mm, thickness 0.25 µm)
- TG Wax (30 m x 0.25 mm, thickness 0.25 µm)
Usage Hours
Hours: 09.00 - 15.00 WIB on weekdays
Provision :
- Consumable materials provided by the user (such as 0.2 µm syringe filter, glass vial, glove, tissue, lab coat)
- Compound target standards and internal standards are provided by the user
- The sample is ready to run and has been filtered with a 0.2 µm syringe filter
- The sample was placed in a 2 mL GC vial
- The time for using the instrument is calculated from the first injection of the sample until the instrument is turned off at a maximum of 15.30 WIB
- The tool operator helps with the technical use of the tool
- The method and analysis results of the GC FID tool are the full responsibility of the user/customer
Sample requirements:
The sample is a volatile compound, the sample dissolves completely in the solvent and there is no precipitate
Sample delivery address
Laboratorium Kawasan Yogyakarta
Kawasan Sains Umar Anggara Jenie BRIN, Jl. Jogja-Wonosari km 31,5, Desa Gading, Kec. Playen, Gunungkidul – Yogyakarta 55861
For further information, please contact us on WA number +628119811586
Application Requirements:
- Photo
- Other Supporting File
File Name | File Size | |
---|---|---|
Service SOP file | 0.05 MB | |
Template Photo | 0 MB | |
Template Other Supporting File | 0 MB |