SERVICE DESCRIPTION | Shimadzu UFLC Type (Analytical) Quantitative, non-preparative analytical chemical testing of solution samples that have been filtered through a 0.2 micron millipore filter and placed in vials (ready to inject). The method used is a standard method optimized…
- Laboratorium Genomik - Fasilitas Layanan Kimia
- KST Cibinong (Soekarno)
Gedung Genomik-KST Soekarno (Cibinong) BRIN Jl Raya Bogor KM 46, Cibinong, Kab. Bogor, Jawa Barat - 08119811575
- genomik@brin.go.id
Marketing Office
Deputi Bidang Infrastruktur Riset dan Inovasi BRIN
layanan_sains@brin.go.id
Shimadzu UFLC Type (Analytical)
Quantitative, non-preparative analytical chemical testing of solution samples that have been filtered through a 0.2 micron millipore filter and placed in vials (ready to inject). The method used is a standard method optimized for HPLC equipment according to the method package type, namely:
1. C-18 column (size 4.6 microns x 250 mm, 5 microns, and 4.6 microns x 150 mm, 5 microns)
2. Poly Diode Array (PDA) Detector / UV Detector
Minimum sample size 0.5 mL in an HPLC vial
Target components for the C-18 column are:
1. Quercetin
2. Glutamic Acid
3. Catechin
4. Isocatechin
Submission Requirements:
- Photo Data File
- Other Supporting Files
- Method
- Standard Solution (If Necessary)
Note: To facilitate verification of registered test samples, customers must complete the TEST DETAILS FORM, which can be downloaded from the "Service Files" --> "Service SOP Files" section. Then, upload the completed form (in .pdf format) along with sample photos in the "Other Supporting Files" and "Photo Data File" sections. Ensure that the name and number of samples registered in the ELSA System match the number of samples listed on the form.
For more information, please contact the genomics service number (08119811575)
Application Requirements:
Quantitative, non-preparative analytical chemical testing of solution samples that have been filtered through a 0.2 micron millipore filter and placed in vials (ready to inject). The method used is a standard method optimized for HPLC equipment according to the method package type, namely:
1. C-18 column (size 4.6 microns x 250 mm, 5 microns, and 4.6 microns x 150 mm, 5 microns)
2. Poly Diode Array (PDA) Detector / UV Detector
Minimum sample size 0.5 mL in an HPLC vial
Target components for the C-18 column are:
1. Quercetin
2. Glutamic Acid
3. Catechin
4. Isocatechin
Submission Requirements:
- Photo Data File
- Other Supporting Files
- Method
- Standard Solution (If Necessary)
Note: To facilitate verification of registered test samples, customers must complete the TEST DETAILS FORM, which can be downloaded from the "Service Files" --> "Service SOP Files" section. Then, upload the completed form (in .pdf format) along with sample photos in the "Other Supporting Files" and "Photo Data File" sections. Ensure that the name and number of samples registered in the ELSA System match the number of samples listed on the form.
For more information, please contact the genomics service number (08119811575)